962 211 594 | ventas@omsaindustrial.com

Navegar Por Las Categorías
  • Automatización Industrial
  • Conectividad AV Industrial
  • Computo Industrial
  • Networking Industrial
  • KVM Industrial
  • Telefonía Móvil Industrial
    • TABLET RUGGED
      • Tablet Windows 10
      • Tablet Windows 11
      • Tablet Android
      • Tablet Para Vehículo
      • Tablet ATEX
      • Tablet Grado Medico
    • NOTEBOOK RUGGED
      • Notebook Windows 10
      • Notebook Windows 11
    • CELULAR RUGGED
      • Celular Rugged Outdoor
    • RUGGED HANDHELD
      • Rugged Handheld Windows
      • Rugged Handheld Android
    • INDUSTRIAL PC COMPUTER
      • Panel PC
      • Touch Panel PC
      • Señalización Digital
  • Telemetría Industrial
  • Videowall Industrial
OMSA Industrial
  • Marcas
    • Antaira
    • Aten
    • Axiomtek
    • Digibird
    • Emdoor
    • ICP Das
    • Rextron
    • SST
    • Welotec
    • Westermo
    • Wlink
  • Nosotros
  • Contáctenos
Menú
InicioAUTOMATIZACIÓN INDUSTRIALAdquisición de Datos RemotoAdquisición de Datos basado en MODBUS RTU M-7011
Producto anterior
M-700
M-700
Regresar a productos
El próximo producto
ZT-2015
ZT-2015

M-7011

Módulo de adquisición de datos de 1 canal de entrada analógica, 1 canal de entrada digital y 2 canales de salida digital. Soporta entrada de termopar, entrada de tensión y entrada de corriente, comunicable a través de Modbus RTU y RS-485. Soporta temperaturas de funcionamiento entre -25 y 75°C (-13F ~ 167F).

Solicitar Información
Categorías: Adquisición de Datos basado en MODBUS RTU, Adquisición de Datos Remoto, AUTOMATIZACIÓN INDUSTRIAL
  • Descripción
  • DESCARGAR
  • ESPECIFICACIONES
Descripción

El M-7011 es un módulo de entrada de termopar de un canal. Proporciona protección y acondicionamiento rentables para una amplia gama de valiosas señales y sistemas de control industrial. Proporcionamos una utilidad DCON gratuita que puede ayudar a los usuarios a configurar y probar los módulos M-7011. Se proporcionan numerosas funciones de biblioteca y programas de demostración que permiten a los usuarios desarrollar programas fácilmente en los sistemas operativos Windows, Linux y DOS. Los usuarios pueden montar los módulos en carril DIN, panel o pared. Los módulos disponen de un bloque de terminales de tornillo para conectar las señales.

RoHS

Referencias y asistencia


    • Manual del usuario
    • Asignación de clavijas
    • Estructura interna de E/S
    • Guía de inicio rápido del módulo M-7000
    • I/M-7000 Manual de introducción
    • I/M-7000 Dimensiones
    • Software de desarrollo y controladores
    • Asignación de direcciones
    • Manual del usuario de DCON Utility
    • Software gratuito EZ Data Logger

DESCARGAR

DESCARGAR

ESPECIFICACIONES
Analog Input
Input Channels 1
Input Type ±15mV, ±50mV, ±100mV,± 500mV , ±1V,± 2.5V ± 20mA (requires optional external 125 ohm resistor) Thermocouple( Type J, K, T, E, R, S, B, N, C)
Resolution 16-bit
Sampling Rate 10 Samples/ Second
Accuracy ±0.05%
Zero Drift ±0.5uV/°C
Span Drift 25ppm/°C
Band Width 5.24Hz
Common Mode Rejection 150dB
Normal Mode Rejection 100dB
Input Impedance 20M Ohms
Intra-module Isolation, Field to Logic 3000 VDC
Digital Input
Channels 1
Logic Level 0 +1V max
Logic Level 1 +3.5V to 30V
Max Input Frequency 50Hz
Min. Pulse Width 1 ms
Digital Output
Channels 2
Output Type Sink, Open Collector to 30V
Output Load 30mA max. per channel
Power dissipation 300 mW
Interface
Interface RS-485, Modbus RTU
Format N, 8, 1
Baudrate 1200 ~ 115200 bps
LED Display
1 LED as Power/ Communication indicator
4 1/2 digits for I-7011D
Power
Input +10 to +30 Vdc
Power Consumption 0.9 W (I-7011) / 1.5W(I-7011D)
Protocol
Support Modbus and DCON Protocol Yes
Watchdog Yes, Module, Communication (Programmable)
Environment
Operating temperature -25°C to 75 °C
Storage temperature -30°C to 75 °C
Humidity 5 to 95%, non-condensing
 
Thermocouple Type Range (°C)
J -210 ~ +760
K -270 ~ +1372
T -270 ~ +400
E -270 ~ +1000
R 0 ~ +1768
S 0 ~ +1768
B 0 ~ +1820
N -270 ~ 1300
C 0 ~ 2320

Productos relacionados

Cerrar

GW-755

Pasarela PROFIBUS a HART. Comunicable a través de los protocolos PROFIBUS, HART y RS-232. Soporta temperaturas de funcionamiento de -25°C ~ +75°C (-13°F ~ 167°F) y tiene un montaje en carril DIN.
Vista rápida
Cerrar

GW-7552-M

Pasarela PROFIBUS a Modbus RTU con caja metálica
Vista rápida
Cerrar

GW-7553-M

PROFIBUS a Modbus TCP Gateway con caja metálica.
Vista rápida
Cerrar

tGW-724

Pequeña puerta de enlace Modbus TCP a RTU/ASCII con PoE, 1 RS-232 y 1 485 puertos (RoHS)
Vista rápida
Cerrar

GW-7552-B

Pasarela PROFIBUS a Modbus RTU con caja de plástico.

Vista rápida
Cerrar

tGW-712

Pequeña puerta de enlace Modbus TCP a RTU/ASCII con PoE y 1 puerto RS-232 (RoHS)
Vista rápida
Cerrar

tGW-718

Pequeña puerta de enlace Modbus TCP a RTU/ASCII con PoE y 1 puerto RS-232/RS-485/RS-422 de 3 cables (ROHS). Soporta temperaturas de funcionamiento de -25 °C a 75 °C (-13 °F a 167 °F)
Vista rápida
Cerrar

tGW-734

Pequeña puerta de enlace Modbus TCP a RTU/ASCII con PoE, 2 RS-232 y 1 485 puertos (RoHS)
Vista rápida
Omsa Industrial Todos los derechos reservados - 2025
OMSA Industrial S.A.C.
  • Menú
  • Productos
  • Automatización Industrial
  • Conectividad AV Industrial
  • Computo Industrial
  • Networking Industrial
  • KVM Industrial
  • Telefonía Móvil Industrial
  • Telemetría Industrial
  • Videowall Industrial
  • Marcas
    • Antaira
    • Aten
    • Axiomtek
    • Digibird
    • Emdoor
    • ICP Das
    • Rextron
    • SST
    • Welotec
    • Westermo
    • Wlink
  • Nosotros
  • Contactenos

Formulario de Producto :




    Usamos cookies para asegurar que te damos la mejor experiencia en nuestra web. Si continúas usando este sitio, asumiremos que estás de acuerdo con ello.